White Rodgers 50a50 Manual
WIRING DIAGRAM - DOWNFLOW/HORIZONTAL 40 The white furnace lead must be connected 50A IGNITION CONTROL (P/N ).
- White Rodgers 50a50 288 Manual
- White Rodgers 50a50 405
- White Rodgers 50a50-288 Manual
- White Rodgers 50a50-209 Manual
- White Rodgers 50a50-405 Manual
This is a BRAND NEW Trane/American Standard Control Circuit Board! The Board # is CNT03797 and the White Rodgers part # is 50A55-486. (OEM Replacement for all the Board Part #s Below). Board comes with instructions, although installation is intuitive. White Rodgers 50A55-843 - Universal Silicon Carbide Integrated Ignition Control - The 50A55-843 Universal Silicon Carbide Integrated Ignition module employs a microprocessor which continually monitors, analyzes and controls the proper operation of the gas burner, inducer and fan. The Universal Module includes an extensive cross-reference, additional jumper wires, an additional wiring harness. White Rodgers SW2: ON 50T35730 50T35-730. SW1-SW2: Check control Safety Timings before setting. White Rodgers1 50A50-110 A Inducer & HSI Connector. OEM American Standard Upgraded Furnace Control Circuit Board 50A50-474 5.0 out of 5 stars 1. 50A50-473 3.0 out of 5 stars 2. OEM White Rodgers Upgraded Furnace Control Circuit Board 50A55-474. White-Rodgers 50A55-843 White Rodgers Universal Integrated Fan Control for Hsi Systems 4.7 out of 5 stars 47. View and Download White Rodgers 50A55-843 installation instructions manual online. Universal Integrated Furnace Control. 50A55-843 controller pdf manual download.
York Diamond 80 furnaces with a White Rodgers 50A board. of the unit wiring diagram and several shots of printed circuit board I can.
WIRING DIAGRAM - DOWNFLOW/HORIZONTAL 40 The white furnace lead must be connected 50A IGNITION CONTROL (P/N ). Replaces All Trane, York, ICP and Amana White-Rodgers models.
FEATURES . Refer to the wiring diagram and wiring table when connecting the 50A 50A - OEM Upgraded White Rogers Furnace Control Circuit Board - - schematron.orgTYPICAL SYSTEM WIRING DIAGRAM HUMIDIFIER Low Voltage (24 VAC) Line Voltage ( VAC) Virtually All White-Rodgers and Competitive Single Stage Carbide and Nitride HSI Systems – 50A N/A F 50A N/A F White-Rodgers Standard 50A N/A E & F 50A N/A F.
York furnace model P3HUC20NC,White rodgers 50A Electronic ignition system.I think thatis what it is called. 3 amp fuse between transformer and thos ignition system keeps blowing.
White Rodgers 50a50 288 Manual
this is in low voltage schematron.org only thing I can think of is white rodgers ignition system is bad. How can I get Trouble shooting chart for this unit and wiring Diagram.
York Diamond 80 furnaces with a Rodgers 50A board York Diamond 80 furnaces with York Diamond 80 furnaces with a White Rodgers 50A board That I'm fairly certain I just fried. exceedingly well focused photo of the unit wiring diagram and several shots of printed circuit board I can coach you on a diagnosis.
Find best value and selection for your White Rodgers 50A50 50A50 search on eBay. World's leading marketplace.
WHITE-RODGERS DIVISION EMERSON ELECTRIC CO. REAVIS ROAD ST.
LOUIS, MISSOURI To prevent electrical shock and/or equipment damage, disconnect electric power to system at main fuse or circuit breaker box until installation is complete. Label all wires prior to disconnection when ser-vicing controls. Wiring errors can cause im-.How do I find a wiring diagram for White Rodgers 50AWhite Rodgers 50A50 50A50 eBay
WHITE-RODGERS | 50A55-474 & 50A55-571 |
Integrated Furnace Controls | |
INSTALLATION INSTRUCTIONS |
Operator: Save these instructions for future use!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE.
DESCRIPTION
The 50A55-474 and 50A55-571 are automatic gas interrupted ignition controls that employ a microprocessor to continually monitor, analyze, and control the proper operation of the gas burner, inducer, and fan.
Signals interpreted during continual surveillance of the thermostat and flame sensing element initiate automatic ignition of the burner, sensing of the flame, and system shut-off during normal operation.
These controls incorporate system fault analysis for quick gas flow shut-off, coupled with automatic ignition retry upon sensing a fault correction.
White Rodgers 50a50 405
PRECAUTIONS
! GENERAL PRECAUTION |
Application of this type of control may cause flame rollout on initial start-up and could cause personal injury and/or property damage.
Replace only with exact model number, including dash number. Failure to use exact replacement control could cause personal injury and/or property damage.
If in doubt about whether your wiring is millivolt, line, or low voltage, have it inspected by a qualified heating and air conditioning contractor or licensed electrician.
Do not exceed the specification ratings.
All wiring must conform to local and national electrical codes and ordinances.
This control is a precision instrument, and should be handled carefully. Rough handling or distorting components could cause the control to malfunction.
CONTENTS | |
Description ............................. | 1 |
Precautions ............................ Mass effect 3 graphics settings. When two cinematic lights are enabled, an additional white light comes into effect, lighting up the left portion of his face and shoulder - this adds much more depth to the scene. | 1 |
Specifications ........................... | 2 |
Installation ............................. | 3 |
Mounting & Wiring | |
Operation .............................. | 6 |
! CAUTION
To prevent electrical shock and/or equipment damage, disconnect electric power to system at main fuse or circuit breaker box until installation is complete.
Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.
This control is not intended for use in locations where it may come in contact with water. Suitable protection must be provided to shield the control from exposure to water (dripping, spraying, rain, etc.).
!WARNING
Do not use on circuits exceeding specified voltage. Higher voltage will damage control and could cause shock or fire hazard.
Do not short out terminals on gas valve or primary control to test. Short or incorrect wiring will damage thermostat and could cause personal injury and/or property damage.
WHITE-RODGERS DIVISION | PART NO. 37-5800C | |
EMERSON ELECTRIC CO. | ||
9797 REAVIS ROAD | Printed in U.S.A. | Replaces 37-5800B |
ST. LOUIS, MISSOURI 63123-5398 | 9751 |
White Rodgers 50a50-288 Manual
SPECIFICATIONS
ELECTRICAL RATINGS [@ 77°F (25°C)]: Input Voltage: 25 VAC 50/60 Hz
Max. Input Current @ 25 VAC: 0.45 amp Relay Load Ratings:
White Rodgers 50a50-209 Manual
Valve Relay: 1.5 amp @ 25 VAC 50/60 Hz 0.6 pf Ignitor Relay: 6.0 amp @ 120 VAC 50/60 Hz
(resistive)
Flame Current Requirements:
Minimum current to insure flame detection: 1 μa DC* Maximum current for non-detection: 0.1 μa DC* Maximum allowable leakage resistance: 100 M ohms
*Measured with a DC microammeter in the flame probe lead
OPERATING TEMPERATURE RANGE:
-40°to 175°F (-40°to 80°C)
HUMIDITY RANGE:
5% to 93% relative humidity (non-condensing)
MOUNTING:
Surface mount multipoise | |
Timing Specs: (@ 60 Hz**) | |
maximum | |
Flame Establishing Time: | 0.8 sec |
Flame Failure Response Time: | 2.0 sec |
**At 50 Hz, all timing specifications should be increased by 20%.
Gases Approved: Natural, Manufactured, Mixed, Liquified Petroleum, and LP Gas Air Mixtures are all approved for use.
TIMING SPECIFICATIONS
(All times are in seconds, unless noted otherwise)
50A55-474 | 50A55-571 | |
PRE-PURGE | 0 | 0 |
TRIAL FOR IGNITION | 4 | 4 |
PERIOD | ||
IGNITION ACTIVATION | 1 | 1 |
PERIOD | ||
RETRIES | 2 times | 2 times |
VALVE SEQUENCE | 12 | 12 |
PERIOD | ||
INTERPURGE | 60 | 60 |
POST-PURGE | 5 | 5 |
LOCKOUT TIME | 300 | 300 |
DELAY TO HEAT ON | 45 | 45 |
DELAY TO HEAT OFF | 60/100/ | 100 |
140/180* | ||
DELAY TO COOL ON | 2 | 2 |
DELAY TO COOL OFF | 0/80* | 0/80† |
MINIMUM IGNITOR | 11 | 11 |
WARM-UP | ||
MAXIMUM IGNITOR | 21 | 21 |
WARM-UP | ||
INITIAL IGNITOR | 17 | 17 |
WARM-UP (1st 64 | ||
attempts) | ||
HUMIDIFIER | YES | NO |
ELECTRONIC AIR | YES | NO |
CLEANER |
*These times will vary depending on option switch position. The control is factory-set at 0 sec. delay to cool off and 100 sec. delay to heat off. See OPERATION section for further information.
†This time will vary depending on the condition of the jumper. With the jumper installed, the delay-to- cool-off is set at 0 seconds. To obtain an 80second delay-to-cool-off, clip the jumper wire and separate the jumper legs.
MOUNTING AND WIRING
White Rodgers 50a50-405 Manual
!WARNING
Do not use on circuits exceeding specified voltage. Higher voltage will damage control and could cause shock or fire hazard.
! CAUTION
To prevent electrical shock and/or equipment damage, disconnect electric power to system at main fuse or circuit breaker box until installation is complete. Failure to earth ground the appliance or reversing the neutral and hot wire connection to the line can cause shock hazard.
Shut off main gas to heating system until installation is complete.
Route and secure all wiring as far from flame as practical to prevent fire and/or equipment damage.
INSTALLATION
NOTE
All wiring should be installed according to local and national electrical codes and ordinances.
The control must be secured to an area that will experience a minimum of vibration and remain below the maximum ambient temperature rating of 175°F. The control is approved for minimum ambient temperatures of -40°F.
Any orientation is acceptable.
Refer to the wiring diagram and wiring table when connecting the 50A55 control to other components of the system.
UL approved, 105°C rated 18 gauge, stranded, 2⁄64” thick insulation wire is recommended for all low voltage safety circuit connections. Refer to 50A55 specification sheet for recommended terminals to mate with those on the control.
UL approved 105°C rated 16 gauge min., stranded, 4⁄64” thick insulation wire is recommended for all line voltage connections. Refer to 50A55 specification sheet for recommended terminals to mate with those on the control.
The 50A55 has only one serviceable part–an automotive type fuse, which protects the low voltage transformer from damage if its output is short-circuited. If the fuse has opened up, remove whatever caused the short circuit and replace the fuse with only a 3 Amp automotive type fuse. If the fuse is not the cause of the control’s problem, replace the entire 50A55 control. There are no other user serviceable parts.